Command Generator Examples

B.5 L2CAP Connection

Procedure

In this scenario, Merlin’s Wand establishes an L2CAP connection.

This procedure assumes that an ACL connection has been established. See
“Establish Baseband Connection” on page 139.

Step 1

Click the L2CAP tab to display the L2CAP drop-down menu.

Step 2

Select Register_PSM from the menu.

Merlin’s Wand must register its PSM channel before it can form an
L2CAP connection.

Step 3

Select or type a PSM from the PSM menu.

Step 4

Select or type the Receive MTU from the Receive MTU
menu (default value can be used).

Step 5

Click Execute.

Step 6

Repeat this procedure for the target device. The target device must
also select a PSM.

Event Log should register “RegisterPsm_Complete.”