1.2

Technical Specifications

Table 1. TRM-203/403 Technical Specifications

TYPE

Portable transformer winding resistance meter

PHYSICAL SPECIFICATIONS

21” W x 17” H x 9” D (53 cm x 43 cm x 24 cm); Weight: 35 lbs (15.8Kg)

OPERATING VOLTAGE

100-240 Vac, 50/60 Hz

RESISTANCE READING

RANGE

1 micro-ohm – 2000 Ohms (TRM-203);
1 micro-ohm – 500 Ohms (TRM-403)

ACCURACY

1 – 19,999 micro-ohms: ±0.5% reading, ±1 count;
20 – 999 milliohms: ±1% reading, ±1 count;
1 -2000 Ohms: ±1.5% reading, ±1 count

TEST CURRENT

1-20A in 1A increments (TRM-203); 1-40A in 1A increments (TRM403)

TEST VOLTAGE

60Vdc charging, 18V DC max during measurement

INPUT CHANNELS

4 input channels for measuring resistance

DISPLAY

Back-lit LCD Screen (128 x 64 pixels), viewable in direct sunlight and low
light levels

PRINTER

Built-in 2.5” wide thermal printer

INTERNAL DATA STORAGE

256 static test records (each can contain up to 111 readings) and 120
dynamic test records

EXTERNAL DATA STORAGE

Up to 999 test records on external USB Flash drive

COMPUTER INTERFACES

RS-232C, USB, and Bluetooth

SAFETY

Designed to meet UL 61010A-1 and Can/CSA C22.2 No 1010.1092
standards

ENVIRONMENT

Operating: -10˚C to 50˚ C (15˚F to +122˚ F); Storage: -30˚ C to 70˚ C (-
22˚F to +158˚ F)

HUMIDITY (MAX)

90% RH @ 40° C (104° F) non-condensing

ALTITUDE (MAX)

2000m (6562 ft) to full safety specifications

CABLES

Four 50-foot test cables, one LTC control cable, one ground cable, one
power cord, one USB cable

OPTIONS

Transportation Case

WARRANTY

One year on parts and labor

NOTE

The above specifications are valid at nominal operating voltage and at a
temperature of 25

°C (77°F). Specifications may change without prior notice.