General specifications – Yokogawa In-Situ Gas Analyzer TDLS200 User Manual

Page 18

Advertising
background image

Standard Accessories

Calibration Cell:

- Used for off-line calibrations and

validations

- Stainless steel 316 with free standing

frame

- Connects Launch and Detect with

72.6cm (28.6") OPL

Flow Cells:

- Used for extracted sample streams at any

location

- 316SS low volume fixed alignment; 50ºC,

5.5 bar (80psig) max

- Enhanced for 200ºC, 20 Bar (290psig),

Sapphire window, Kalrez o-rings and can
be constructed from 316SS, Monel A400,
Hastelloy C-276, Carpenter 20 and other
materials on request to suit the process

Isolation Flanges:

- Used for additional protection for in-situ

or by-pass installations

- 2” or 3” 150# or 300# ANSI RF, 4”150#,

DN80 PN16 welded 5/8” or M16” bolt
studs included sapphire 20 Bar (290 psig)
or BK-7 5.5bar (80 psig) isolation window

- Kalrez window seal o-ring rated max

200ºC

- 316SS, Monel A400, Hastelloy C-276,

Carpenter 20, other on request

Note: Must use in conjunction with alignment flanges

Utility Panel:

- Used for convenient field installation of

utilities, configurations for

- Single, dual or four analyzers

- Manual or automatic on-line validation

(controlled by analyzer)

- Safe area (GP), Div 2 purged or non-

purged, ATEX CAT 2G components

- Purge flowmeters with integral needle

valve, glass tube variable area

- Swagelok double ferrule stainless steel tube

fittings and tubing standard

- Panel mounted or fiberglass (NEMA 4X/

IP65), with viewing window

- 5A 24VDC power supply, output to

analyzer – requires VAC input power

Note: Custom configuration available to suit customer requirements

Integration:

- Used for convenient analyzer & extractive

system/flow cell integration

- Free standing frame, galvanized steel with

304SS roof

- Fiberglass enclosure with powder coated

steel frame

- Heat tracing and insulation for flow cells

and sample handling

- 316SS and/or Monel A400 wetted parts –

other on request

- Sample handling and conditioning

systems to suit applications

- Stream switching manual or automatic

(controlled by analyzer)

Note: Custom configuration available to suit customer requirements

Display and Software functions

TruePeak Software has multiple levels, the default (or start page) is
the Main Menu:

Main Menu Displays: - Concentration & Units (% or ppm)

- Transmission %

- Status (warm-up, OK, Warning, Fault,

etc.)

- Temperature (Fixed, Active Ambient or

Active)

- Pressure (Fixed or Active)

Main Menu:
Basic Menu

- Configure, 3 functions

- View Spectra, 2 functions

- Data, 3 sub-menus

- Trends

Advanced Menu

- Configure, 9 sub-menus

(User Password)

- Calibrate & Validate, 3 sub-menus

- Data, 4 sub-menus

- Trends,

Active Alarms

- List of active alarms

Shut Down Analyzer

- Instructions to close TruePeak local or

VAC

Calibration Functions:
Off-line Calibrations:

- Zero calibration

- Zero off-set

- Span calibration

- Transmission

- Dark current

- peak search

Off-line Validations:

- Check gas #1

- Check gas #2

- Check gas #3

On-Line Validations:

- Manual

- Automatic

Setup Functions:
Configuration:

- Process Path Length

- Pressure

- Temperature

- Units

- System I/O

- System

- Valve Control

- Laser Spectra & Control

Diagnostics:
Warnings include:

- Detector signal low

- Transmission low

- Spectrum noise high

- Process pressure out of range

- Process temperature out of range

- Concentration out of range

- Board temperature out of range

- Validation failure

Faults include:

- Laser temperature out of range

- Detector signal high

- Detector signal lost

- Peak center out of range

Output Settings:
Analog Output:

- Channel 1

- Channel 2

- Channel 3

- Warning Mode

- Fault Mode

- Field Loop Check

- AO CH calibration

3-3

IM 11Y01B01-01E-A 6th Edition :Feb 13, 2013-00

<3. GENERAL SPECIFICATIONS>