Yokogawa DO202 2-Wire Dissolved Oxygen Analyzer User Manual

Page 22

Advertising
background image

IM 12A00A01-61E

Foundation Fieldbus 3-17

3-17

Realtive

Index

Parameters

Mnemonic

View

1

View

2

View

3

View

4

30

XD_MAN_ID[32]

31

TEMPERATURE_
COEFF

4

32

CONCENTRATION

5

5

33

TERTIARY_VALUE

5

5

34

REFERENCE_
TEMPERATURE

4

35

COMP_METHOD

1

1

36

COMP_MATRIX_SEL

1

37

TERTIARY_COMP_
METHOD

1

38

TERT_TEMPERATURE_
COEFF

4

39

ALARM_SUM

8

8

40

DEV_ALARM

4

4

41

LOGBOOK1_RESET

42

LOGBOOK1_EVENT

43

LOGBOOK2_RESET

44

LOGBOOK2_EVENT

45

LOGBOOK_CONFIG[16]

16

46

TEST_1

58

TEST_13

59

CALIB_SENSOR_
CONST

4

60

MATRIX_TEMP_RANGE

61

SOLUTION_1

62

SOLUTION_2

63

SOLUTION_3

64

SOLUTION_4

65

SOLUTION_5

66

CONCENTRATION_
MEASUREMENT

1

67

CONCENTRATION_0

68

CONCENTRATION_100

69

CONCENTRATION_
TABLE_LOW

70

CONCENTRATION_
TABLE_MID

71

CONCENTRATION_
TABLE_HIGH

72

E5_LIMIT

4

73

E6_LIMIT

4

74

DISPLAY_RESOLUTION

1

75

PASSCODE_
MAINTENANCE

2

76

PASSCODE_
COMMISSIONING

2

77

PASSCODE_SERVICE

2

78

ERROR_CONFIG

4

79

CONFIGURATION

4

80

TRANSMITTER_TIME

6

81

SOFTDWN_TEST

1

TOTALS (# BYTES)

43

17

54

96

Table 3.17 View Object for Transducer Block DO202

Realtive

Index

Parameters

Mnemonic

View

1

View

2

View

3

View

4

0

BLK_DATA

1

ST_REV

2

2

2

2

2

TAG_DESC[32]

3

STRATEGY

2

4

ALERT_KEY

1

5

MODE_BLK

4

4

6

BLOCK_ERR

2

2

7

UPDATE_EVT

8

BLOCK_ALM

Realtive

Index

Parameters

Mnemonic

View

1

View

2

View

3

View

4

9

TRANSDUCER_
DIRECTORY[2]

10

TRANSDUCER_TYPE

2

2

2

2

11

XD_ERROR

1

1

12

COLLECTION_
DIRECTORY[7]

13

PRIMARY_VALUE_TYPE

2

14

PRIMARY_VALUE

5

5

15

PRIMARY_VALUE_
RANGE

11

16

PRIMARY_VALUE_UNIT

2

17

SENSOR_TYPE_OXYGEN

2

18

SAMPLE_CAL

19

ZERO_CURRENT

4

20

SENSITIVITY

4

21

AMP_STABILIZE_TIME

4

22

AMP_SPAN_
STABILIZE _VALUE

4

23

AMP_ZERO_
STABILIZE_VALUE

4

24

SALINITY

4

25

BAR_PRESSURE

4

26

BAR_PRESSURE_UNIT

2

27

PERCENT_SATURATION_
PRESSURE

4

28

CHLORINE_
CALIBRATION_RANGES

29

SECONDARY_VALUE

5

5

30

SECONDARY_
VALUE_UNIT

2

31

SENSOR_TEMP_COMP

1

32

SENSOR_TEMP_
MAN_VALUE

4

33

SENSOR_TYPE_TEMP

2

34

TEMP_SENSOR_CAL

4

35

SENSOR_CURRENT

5

5

36

PERCENT_SATURATION

5

5

37

ZERO_CURRENT_LIMIT

4

38

ZERO_CAL

39

RESERVED1

40

RESERVED2

41

RESERVED3

42

TRANSMITTER_TIME[6]

6

43

PASSCODE_
MAINTENANCE

44

PASSCODE_
COMMISSIONING

45

PASSCODE_SERVICE

46

LOGBOOK1_RESET

47

LOGBOOK1_EVENT

48

LOGBOOK2_RESET

49

LOGBOOK2_EVENT

50

LOGBOOK_CONFIG[25]

25

51

CALL_MAINT_TIME_
RELOAD

1

52

CALL_MAINT_TIME_
COUNTDOWN

1

53

ERROR_CONFIG

4

54

CONFIGURATION

4

55

ALARM_SUM

8

8

56

DEV_ALARM

4

4

57

TEST_1

69

TEST_13

70

SOFTDWN_TEST

1

TOTALS (# BYTES)

43

12

50

102

Table 3.16� View Object for Transducer Block SC202/ISC202
(contineous)

Table 3.17 View Object for Transducer Block DO202
(continues)