4-3. transducer block parameters, 4-3-1. transducer block parameters ph202, 4-3. transducer block parameters -9 – Yokogawa DO202 2-Wire Dissolved Oxygen Analyzer User Manual

Page 67: 4-3-1. transducer block parameters ph202 -9

Advertising
background image

Profibus 4-9

4-4-3. Transducer block parameters

4-4-3-1. Transducer block parameters PH202

Parameter

default

Alternatives

Unit r/W Slot, Index data Type

(byte,bit) (bytes)

Primary value Type

111(pH)

R

4, 27

unsigned16 (2)

Measured Value

pH

R

4, 28

DS-33 (5)

Status

R

4, 28

DS-33 (5)

Sensor type pH

pH/ORP sensor(160)

pH/ORP sensor(160)

R

4, 30

unsigned16 (2)

Sensor mV

mV

R

4, 31

float (4)

Secondary value Parameters

Value

ºC

R

4, 42

DS-33 (5)

Status

R

4, 42

DS-33 (5)

Secondary value unit

˚C

˚F

R/W 4, 43

unsigned16 (2)

Sensor temp comp

Automatic(2)

Off(0), Manual(1)

R/W 4, 44

unsigned8 (1)

Sensor temp man value

ºC

R/W 4, 45

float (4)

Temperature sensor

Pt1000(148)

Pt100(128), 5k1(150), 3kBalco(145),

R/W 4, 46

unsigned16 (2)

8k55(151), 350(153), PTC10k(158),

6k8(157)

Temp. connection type

1

R

4, 47

unsigned8 (1)

Process compensation

Disabled(0)

Enabled(1)

R/W 4, 167(1.0) unsigned32 (4)

Temperature Coefficient

mV/

10ºC R/W 4, 159

float (4)

Tertiary value Parameters

Tertiary value type

None(1)

ORP(2), rH(3)

R

4, 48

unsigned16 (2)

Value

mV

R

4, 49

DS-33 (5)

Status

R

4, 49

DS-33 (5)

Calibration Parameters

Calibration High

pH

R/W 4, 32

float (4)

Calibration Low

pH

R/W 4, 33

float (4)

Cal min span

pH

R

4, 34

float (4)

Slope check

Enabled(1)

Disabled(0)

R/W 4, 167(1.1) unsigned32 (4)

Slope

%

R/W 4, 35

float (4)

Slope unit

%(1342)

%(1342)

R

4, 36

unsigned16 (2)

Zero check

Enabled(1)

Disabled(0)

R/W 4, 167(1.0) unsigned32 (4)

Zero

mV

R/W 4, 37

float (4)

Zero unit

mV(1243)

pH(1422)

R/W 4, 38

unsigned16 (2)

Isopotential pH

pH

R/W 4, 39

float (4)

Tertiary zero

mV

R/W 4, 51

float (4)

Calibration method

not calibrated(0)

one point(107), two point(108), other(255)

R/W 4, 40

unsigned8 (1)

Date of Calibration

R

4, 41

DS-21

Stable Time

5.0 sec

S

R/W 4, 97

float (4)

Stable Value

0.02pH

pH

R/W 4, 98

float(4)

diagnostic Settings

Glass impedance

ohm R

4, 52

float (4)

Glass impedance Lo Lim

ohm R/W 4, 101

float (4)

Glass impedance Hi Lim

ohm R/W 4, 102

float (4)

Glass impedance check Enabled(1)

Disabled(0)

R/W 4, 167(2.2) unsigned32 (4)

Glass impedance circuit High(1)

Low(0)

R/W 4, 167(2.0) unsigned32 (4)

Glass impedance comp. Enabled(1)

Disabled(0)

R/W 4, 167(2.1) unsigned32 (4)

Glass impedance exceeds

low limit (E4.1)

Hard fail(1)

Soft fail(0)

R/W 4, 166(2.2) unsigned32 (4)

Glass impedance exceeds

high limit (E5.1)

Hard fail(1)

Soft fail(0)

R/W 4, 166(2.3) unsigned32 (4)

Reference impedance

ohm R

4, 53

float (4)

Reference impedance

low limit

ohm R/W 4, 103

float (4)

Reference impedance

high limit

ohm R/W 4, 104

float (4)

Reference impedance check

Enabled(1)

Disabled(0)

R/W 4, 167(2.5) unsigned32 (4)