Commands

M-4662

1

2

3

4

5

6

7

App

Index

XM

Sets the memory sample

condition

Syntax

XM p1<terminator>
p1

Data type

DISPLAY

Display data

EVENT

Event data

E+D

Display data and event data

Query

XM?

Example

Set the memory sampling condition to display
data.
XMDISPLAY

RF

Sets the key lock function

p1=KEY

Syntax

RF p1,p2,p3,p4,p5,p6,p7<terminator>
p1

Type (KEY)

p2

START/STOP key (FREE, LOCK)

p3

HISTORY key (FREE, LOCK)

p4

MENU key (FREE, LOCK)

p5

USER key (FREE, LOCK)

p6

DISP/ENTER key (FREE, LOCK)

p7

T/DIV key (FREE, LOCK)

p1=FUNC (function keys)

Syntax

RF p1,p2,p3,p4,p5,p6,p7,p8
<terminator>
p1

Type (FUNC)

p2

Alarm acknowledge (FREE, LOCK)

p3

Message/batch (FREE, LOCK)

p4

Math (FREE, LOCK)

p5

Data save (FREE, LOCK)

p6

E-mail/FTP (FREE, LOCK)

p7

Time set (FREE, LOCK)

p8

Display function (FREE, LOCK)

p1=MEDIA (external storage media)

Syntax

RF p1,p2,p3<terminator>
p1

Type (MEDIA)

p2

External storage media operation (FREE,

LOCK)

p3

Load setup (FREE, LOCK)

Query

RF[ p1]?

Example

Lock the MENU key (leave other keys unlocked).
RFKEY,FREE,FREE,LOCK,FREE,FREE,FREE

RN

Sets basic login settings

Syntax

RN p1,p2<terminator>
p1

Auto logout (OFF, 1MIN, 2MIN, 5MIN,

10MIN)

p2

Operation when logged out

OFF

Disable the MV operation

DISPLAY

Allow only display-related
operations

Query

RN?

Example

Set the auto logout time to 1 minute, and disable
the MV operation when logged out.
RN1MIN,OFF

RP

Sets login and user limitations

Syntax

RP p1,p2,···<terminator>
p1

User limit number (1 to 10)

p2

User limit item (KEY, FUNC, MEDIA)

Description Parameters p3 and subsequent parameters vary

depending on the p2 setting as follows:

p2=KEY

p3

START/STOP key (FREE, LOCK)

p4

HISTORY key (FREE, LOCK)

p5

MENU key (FREE, LOCK)

p6

USER key (FREE, LOCK)

p7

DISP/ENTER key (FREE, LOCK)

p8

T/DIV key (FREE, LOCK)

p2=FUNC (function keys)

p3

Alarm acknowledge (FREE, LOCK)

p4

Message/batch (FREE, LOCK)

p5

Math (FREE, LOCK)

p6

Data save (FREE, LOCK)

p7

E-mail/FTP (FREE, LOCK)

p8

Time set (FREE, LOCK)

p9

Display function (FREE, LOCK)

Query

RP[ p1,[ p2]]?

Example

Lock the START, HISTORY, and DISP/ENTER
keys.
RP1,KEY,LOCK,LOCK,,,LOCK

p2=MEDIA (external storage media)

Syntax

RP p1,p2,p3<terminator>
p2

User limit item (MEDIA)

p3

External storage media operation (FREE,

LOCK)

p4

Load setup (FREE, LOCK)

Query

RP[p1]?

Example

Limit access to the external storage medium and
the loading of setup data.
RPMEDIA,LOCK,LOCK

Description If key lock is enabled, setup data cannot be

loaded. You can place limitations on the loading
of setup data for users that are logged in.