5-30

M-4662

Configured Channel Information Data

• The MV returns the configured channel information data in response to an FE5

command.

• The ID number of the output format is 25.
• You can use the CB command to specify whether or not the MV will return data of

measurement channels set to skip and computation channels set to OFF.

• The figure below indicates the format.

Number of blocks

Block size

Configured channel information block 1

...

Configured channel information block n

(Reserved) (Reserved)

2 bytes

1 byte

1 byte

1 byte

1 byte

Version (Reserved)

2 bytes

Format Details

Item

Description

Output Value

Version

Format version

1

Number of blocks

*

Number of configured channel information blocks

Up to 348

Block size

*

Size of the of configured channel information blocks

72

Block 1 to n

Configured channel information blocks

Up to 25056 bytes

See Block Details.

* Returned in the byte order specified by the BO command.

Block Details

Item

Number of Bytes Description

Channel number

*

2

1 to 440

Decimal place

1

0 to 4

(Reserved)

1

0

Channel type

*

4

2H for measurement and external input channels
and 4H for computation channels.

This value is ORed with 800H when the range mode
is DI or 8000H when the range mode is skip.

Unit information

8

The terminator is ‘\0.’

Tag information

24

The terminator is ‘\0.’

Minimum input value

*

4

Measurement channels: Allowable input range under

the current setting

Maximum input value

*

4

Computation channels: –9999999, +99999999

(fixed)

External input channels: –30000, +30000 (fixed)

Span lower limit

*

4

Measurement channels (when scaling is not used):

Same value as the MV span setting

Span upper limit

*

4

Measurement channels (when scaling is used):

Same value as the MV scale setting

Computation and external input channels:

Same value as the MV span setting

Scale lower limit

*

4

Measurement channels:

Same value as the span

Scale upper limit

*

4

Computation and external input channels:

Same value as the span

FIFO type

*

2

1

Area in the FIFO

*

2

Indicates the position of its own channel in the FIFO
block of one sample.

The value starts from zero.

(Reserved)

4

0

* Returned in the byte order specified by the BO command.