7.1

Ethernet Interface Specifications

Basic Specifications

Electrical and mechanical specifications:

Conforms to IEEE 802.3 (Ethernet frames
conform to the DIX specification)

Transmission medium type:

10BASE-T

Protocol:

TCP, IP, UDP, ICMP, ARP, FTP, HTTP, SNTP,
SMTP

Maximum Number of Connections and Number of Simultaneous Uses

The following table indicates the maximum number of connections, the number of
simultaneous uses (number of users that can use a function simultaneously), and the MV
port number for each function.

Function

Maximum Number
of Connections

Number of
Simultaneous Uses

Port number

4

Administrator User

Setting/measurement server

3

1

2

1

34260/tcp

2

Maintenance/test server

1

1

1

1

34261/tcp

2

FTP server

2

2

2

1

21/tcp

3

Web server (HTTP)

1

80/tcp

3

SNTP server

123/udp

3

Modbus server

2

502/tcp

3

Instrument information server

34264/udp

2

1 Users have limitations. See section 1.1 for details.
2 The port number is fixed.
3 The default port number. You can set a value in the range of 1 to 65535. Use the default port

number unless there is a specific reason not to do so.

4 Make sure that each port number is unique.