Tu sets an event action, Sk sets a computation constant – Yokogawa Button Operated MV2000 User Manual

Page 91

Advertising
background image

4-18

4.4 Setting Commands (Setting)

M-4662

If p2 is set to MONTH (day/time designation)

Syntax

TK p1,p2,p3,p4,p5<terminator>
p1

Timer number (1 to 4)

p2

Timer designation (MONTH)

p3

Day (1 to 28)

p4

Time (hh:mm) (00:00 to 23:59)

p5

Timer operation (SINGLE, REPEAT)

If p2 is set to YEAR (month/day/time designation)

Syntax

TK p1,p2,p3,p4,p5,p6<terminator>
p1

Timer number (1 to 4)

p2

Timer designation (YEAR)

p3

Month designation (JAN, FEB, MAR, APR,

MAY, JUN, JUL, AUG, SEP, OCT, NOV,
DEC)

p4

Day designation (1 to 31) The selectable

range varies on the specified month.

P5

Time (hh:mm) (00:00 to 23:59)

p6

Timer operation (SINGLE, REPEAT)

Example

Specify 8:30 on April 28 every year for timer
number 3.
TK3,APR,28,08:30,REPEAT

Query

TK[ p1]?

Example

Specify hour 21 every Thursday for timer number
2.
TK2,WEEK,THU,21:00,REPEAT

TU

Sets an event action

Syntax

TU p1,p2,p3,p4,p5,p6,p7<terminator>
p1

Logic number (1 to 40)

p2

Event type

NONE
REMOTE
RELAY

Alarm output relay

SWITCH

Internal switch

ALARM

Alarm occurrence

TIMER

Timer expiry

MATCHTIMETIMER

Match time expiry

USERKEY

USER key

p3

Event detail

p2=REMOTE

Remote number (1 to
8)

p2=RELAY

Relay number

p2=SWITCH

Internal switch
number

p2=TIMER

Timer number (1 to 4)

p2=MATCHTIMETIMER Match timer number

(1 to 4)

p2=Other

Space

p4

Action type

MEMORYSTART/STOP
MEMORYSTART
MEMORYSTOP
TRIGGER

Event trigger

ALARMACK

Alarm acknowledge

MATHSTART/STOP
MATHSTART
MATHSTOP
MATHRESET

SAVEDISPLAY

Save display data to
an external storage
medium

SAVEEVENT

Save event data to an
external storage medium

MESSAGE

Write a message

SNAPSHOT
MANUALSAMPLE
TIMERRESET

Reset the relative timer

DISPLAYRATE1/2

Switch the trend update

rate

DISPLAYGROUPCHANGE

Switch the display group

FLAG

Raise a flag

TIMEADJUST

Synchronize the clock

PANELLOAD

Load settings

p5

Event detail 2

p4=TIMERRESET Timer number (1 to 4)
p4=DISPLAYGROUPCHANGE Group number
p4=FLAG

Flag number (1 to 8)

p4=MESSAGE

Message number (1 to

100)

p4=PANELLOAD Setup file number (1 to

3)

p6

Event detail 3

p4=MESSAGE

Method of specifying

the destination where
messages are written

ALL

All display groups

SELECT

A specified display

group

p7

Event detail 4

If p6 is set to SELECT Group number

Some p4 parameters (action type) are not
selectable depending on p2 (event type).

Some p4 parameters (action type) are not
selectable depending on the settings or on the
installation of options.

Query

TU[ p1]?

Example

Execute memory start with the remote control input
(terminal 1).
TUREMOTE,1,MEMORYSTART

Description Set parameter p3 (relay number, internal switch)

according to the table in section 4.3.

SK

Sets a computation constant

Syntax

SK p1,p2<terminator>
p1

Constants number

p2

Constant (–9.9999E+29 to –1.0000E–30,

0, 1.0000E–30 to 9.9999E+29, 5 significant
digits)

Query

SK[ p1]?

Example

Set constants number K01 to 1.0000E–10.
SKK01,1.0000E-10

Description • You can execute this command on models

with the /M1 math option.

• You cannot execute this command while the

MV is measuring or computing.

• Set parameter p1 according to the table in

section 4.3.

Advertising