Updating firmware using xmodem, Updating firmware using xmodem -2 – ADTRAN ATLAS 810 Plus User Manual

Page 126

Advertising
background image

Chapter 10. Updating Firmware

10-2

ATLAS 810

PLUS

User Manual

61200266L1-1

Updating Firmware using XMODEM

Before beginning this procedure,

you must have a level 2 password for updating any module within
ATLAS 810

PLUS

. Please consult the ATLAS 810

PLUS

administrator if you

do not know the password.

you must obtain the appropriate update file for the particular module
from ADTRAN Technical Support at (888) 4ADTRAN (423-8726).

you may want to review Update Firmware on page 6-16.

Instructions for Updating Firmware Using XMODEM

Step

Action

1

Using a VT-100 terminal emulation communication software
package which contains XMODEM protocol support, log in to

ATLAS 810

PLUS

.

2

Select

System Utility

/

Update Firmware (see

Figure 10-1

).

3

Move the cursor to Module Slot, and press

Enter

. Select the

appropriate module slot to update. To update multiple modules of
the same type, select All Modules of a Type from Module Slot.

(Only upgradable modules are displayed as choices for Module
Type
when updating All Modules of a Type in the ATLAS.)

4

Select XMODEM for Transfer Method.

5

From Restart Schedule, select the time for the module to perform
a restart after completing the update process (see Restart
Schedule on page 6-17
).

6

View Current Update Status to verify the progress of the current
firmware update or any errors encountered during the download
process (see Current Update Status on page 6-18).

7

Select Begin Firmware Update to start the update process. Enter

Y

to confirm the transfer and to set up the module to receive the

XMODEM upload.

When ATLAS is ready to receive the XMODEM upload, the menu
screen will clear and display

Awaiting XMODEM Upload…… <CTRL-

X> to Cancel

. If this does not appear, please review the steps

above for possible configuration errors.