Chapter 2. Installation

61200266L1-1

ATLAS 810

PLUS

User Manual

2-3

A supplementary equipment grounding conductor shall be installed be-
tween the product or system and ground that is in addition to the equipment
grounding conductor in the power supply cord.

The supplementary equipment grounding conductor shall not be smaller in
size than the ungrounded branch-circuit supply conductors. The supple-
mentary equipment grounding conductor shall be connected to the product
at the terminal provided, and shall be connected to ground in a manner that
will retain the ground connection when the product is unplugged from the
receptacle. The connection to ground of the supplementary equipment
grounding conductor shall be in compliance with the rules for terminating
bonding jumpers at Part K or Article 250 of the National Electrical Code,
ANSI/NFPA 70. Termination of the supplementary equipment grounding
conductor is permitted to be made to building steel, to a metal electrical race-
way system, or to any grounded item that is permanently and reliably con-
nected to the electrical service equipment ground.

REVIEW THE REAR PANEL DESIGN

The ATLAS 810

PLUS

rear panel contains eight slots for housing option mod-

ules which provide a variety of additional resources and data ports. All slots
are functionally identical except slots 7 and 8, which can also accommodate
an optional power supply for redundancy. See Figure 2-1 (AC powered unit)
and Figure 2-2 (DC powered unit).

Figure 2-1. AC Powered ATLAS 810

PLUS

Rear Panel

4A/25OV SLOBLO

I

O

CONTROL

/CHAIN

IN

OUT

MON

10 BASE T

NTWK 1 NTWK 2

CAUTION:

CAUTION: FOR CONTINUED PROTECTION
AGAINST RISK OF FIRE REPLACE ONLY
WITH SAME TYPE AND RATING OF FUSE.

1

2

3

4

5

6

7

8

90-130/190-240VAC

4A/2A, 50/60 HZ

REMOVE POWER CORD PRIOR TO

ALL EMPTY SLOTS MUST BE COVERED WITH BLANK PANELS

CAUTION-RISK OF
ELECTRIC SHOCK

SUPPLAMENTAL EARTH GROUND MUST BE CONNECTED

PRIOR TO CONNECTION OF TELECOMMUNICATION WIRING

REMOVAL OF POWER SUPPLY

NC NO COM GND

ALARM

CAUTION: MAINTENANCE TO BE PERFORMED BY TRAINED SERVICE PERSONNEL ONLY

Power Switch

Control/

Chain In

Interface of

Chain In

Control/Chain Out

Connects to Chain

In of another unit

10 Base T

RJ-48C

Connection Port

MON (Monitor)

Bantam test jack

NTWK1

RJ-48C

Connection Port

NTWK2

RJ-48C

Connection Port

Supplemental

earth ground lug

Alarm Relay

Connection

Blank panel covering an

unused option slot