Appendix B. Troubleshooting

B-2

ATLAS 810

PLUS

User Manual

61200266L1-1

Cannot pass data from T1 interface to V.35 port

Misconfiguration, improper cabling

•

Verify that the T1 signal is being received. If not, check that the cabling
is correct.

•

Verify that the T1 is being received without errors. If not, double-check
that framing and coding are set properly.

•

Verify that desired dedicated map is active.

•

Verify that bandwidth is mapped to the correct V.35 port.

•

Verify that the V.35 port is set to the correct data rate (terminal inter-
face).

•

Check T1 performance using the terminal interface; if excessive errors,
report fault to the Telco.

•

Verify proper state of DTE signals via the terminal interface or the
LCD front panel.

Switched calls are not working

Misconfiguration

•

Verify that the end point has proper call accept/reject criteria. For RBS
applications, check signaling bit status on the terminal interface for
proper operation.

•

Verify that the end point is set up for correct signaling.

Cannot communicate with ATLAS USING VT-100
connected to the Control/Chain In Port

Misconfiguration, improper cabling

•

Verify that ATLAS is receiving commands (press keys on terminal and
verify that the received byte count in the front panel increments).

•

Check cabling, verify that the chain port rate matches that of the at-
tached terminal; check chain port status leads on the front panel.