Chain port rx bytes, Chain port overrun errs, Chain port framing errs – ADTRAN ATLAS 810 Plus User Manual

Page 59: Clear chain port countrs, System config, Primary timing source, Backup timing source, System config -7, Primary timing source -7, Figure 6-3. system configuration menu -7

Advertising
background image

Chapter 6. Terminal Menu and System Control

61200266L1-1

ATLAS 810

PLUS

User Manual

6-7

» Chain Port Rx

Bytes

Read security: 5
Displays the number of received data bytes.

» Chain Port

Overrun Errs

Read security: 5
Displays the number of overrun errors.

» Chain Port

Framing Errs

Read security: 5
Displays the number of received framing errors.

» Clear Chain Port

Countrs

Clears all chain port counters. Press

Y

to activate command.

>

SYSTEM
CONFIG

The

System Config

menu allows you to set up the ATLAS operational con-

figuration. Figure 6-3 shows the items included in this menu.

Figure 6-3. System Configuration Menu

» Primary Timing

Source

Write security: 3; Read security: 5
Selects the primary timing source. You can select either

INTERNAL

or a port

from one of the installed modules.

» Backup Timing

Source

Write security: 3; Read security: 5
Selects the secondary timing source. You can select either

INTERNAL

or a

port from one of the installed modules. ATLAS 810

PLUS

uses the backup

timing source if the primary timing source goes into alarm. The

Backup

Timing Source

should be different from the

Primary Timing Source

.

Advertising