Chapter 7. Modules Terminal Menu

61200266L1-1

ATLAS 810

PLUS

User Manual

7-3

» State

Read security:5
Displays whether the module is online of offline. Even though a module is
physically installed, it must be marked

Online

for it to be considered an

available resource. This parameter allows an installed module to be marked

Offline

, which may be useful in system troubleshooting. If you choose

Offline

, the module will not be in alarm condition, but will display

Offline

.

» Status

Read security:5
Displays status information on the ATLAS 810

PLUS

T1/PRI ports and other

installed modules as follows:

» Rev

Read security:5
Displays the hardware revision of the ATLAS 810

PLUS

.

Once a module is installed, the state must be set to Online in
order for the ATLAS to utilize the module for any data bandwidth.

Online

The module is enabled and is responding to the system
controller’s status polls. This is the normal response of the
system.

No Response

The module is enabled but is not responding to the sys-
tem controller’s status polls. This response indicates a
problem in the system or that the module is not installed.

Empty

The system controller has not detected the presence of a
module in the system, nor has a module been manually
enabled for this option slot.

Offline

The module is installed but has been taken Offline by a
user. The module is still responding to controller polls.

Offline/No
Response:

The module is installed but has been taken Offline by a
user. The module is not responding to polls.

Not Supported

The module is not supported by the current system con-
figuration.