Chapter 6. Terminal Menu and System Control

6-12

ATLAS 810

PLUS

User Manual

61200266L1-1

(ESF) DS1. The default value is 132,960 CRC errors for an approximate BER
level of 10E-5.

Total LES Thrsh

The DS1 performance monitor Threshold Value for the Total Line Errored
Seconds (LES) parameter. The default value is 648 for an approximate BER
level of 10E-5.

Total LCV Thrsh

The DS1 performance monitor Threshold Value for the Current 15 minute
Line Code Violations (LCV) parameter. The default value is 133,400 for an
approximate BER level of 10E-5.

» Event Logging

Write security: 3; Read security: 5
Sets the system event severity level threshold for each of the
ATLAS 810

PLUS

system event types. Whenever a system event occurs, that

event is logged if the event’s severity level is equal to or more severe than
the event type’s current threshold setting. See System Event Logging on page
A-1 fo
r detailed information on the system events.

» Syslog Setup

Write security: 3; Read security: 5
Configures the ATLAS Syslog client for use with a Syslog server (supplied
on ADTRAN /Utility disk or available on most UNIX platforms).

»» Transmission

Enables or disables the transmission of log events to the external Syslog
server.

»» Host IP Address

Lists the IP address of the external server that is running the Syslog host dae-
mon.

»» Host Facility

Specifies the facility destination of log events. Facilities are located on the
host and are managed by the Syslog host daemon running on either a UNIX
machine or a PC.

» Real Time Clock

Write security: 3; Read security: 5
Provides access to the following two options that you can review and edit:

»» Current Time/Date

Displays the current date and time, including seconds. To edit this field, en-
ter the time in 24-hour format (such as 23:00:00 for 11:00 pm), and enter the
date in mm-dd-yyyy format (for example, 09-23-1998).

»» Auto Daylight

Savings

When enabled, automatically updates the time and date when Daylight Sav-
ings Time starts and, also, when Standard Time starts.