IP Video Testing with the FrameScope Pro
6
N2620A User’s Guide
151
Setting Pass or Fail and Rating Criteria for Results
The pass or fail criterion for each test parameter can be
configured. The FrameScope Pro supports the following ratings.
•
1
(Poor): If a measurement value is greater than the
user-defined value for RATING 2
•
2
(Marginal): If a measurement value is less than or equal to
the user-defined value for RATING 2, and greater than the
user-defined value for RATING 3
•
3
(Good): If a measurement value is less than or equal to the
user-defined value for RATING 3
To set the ratings, perform the following procedure.
1
Press Rating on the main IPTV Setting screen.
2
The FrameScope Pro will display the RTP Rating screen for
the RTP measurements. Type in the rating values for the
following RTP measurements.
•
Jitter (in ms)
•
Loss ratio (in %)