2

Press Traffic Generator to display the Traffic Generator screen.
To prevent network disruption or unauthorized usage for
security purposes, a password may be configured.

3

On the Parameters tab, the desired traffic characteristics can
be configured by pressing each parameter box button (for
example, Frame Length and Frame Rate) to type in the desired
value using the on-screen keypad. Refer to

Chapter 8

,

“Traffic Generation” on page 239 for further details on these
parameters.

4

For Frame Length, if Table option is selected, you can insert up
to 32 different frame lengths.

5

Select either CRC Error, Short Frame, or Long Frame for the type
of error desired to be injected into the generated traffic.
Refer to

Chapter 8

, “Traffic Generation” on page 239 for

further details on these errors.