Setting the network for rfc 2544 tests – Agilent Technologies N2620A User Manual

Page 70

Advertising
background image

52

N2620A User’s Guide

2

Network Testing with the FrameScope Pro

Setting the Network for RFC 2544 Tests

The network settings have to be adjusted to ensure that the test
can run.

•

NAT has to be disabled or the IP and MAC addresses of the
FrameScope Pro should be allowed to pass through.

•

Firewalls have to be disabled or should allow the IP and MAC
addresses of the FrameScope Pro to pass through.

•

ICMP ports need to be freed up for the network-under-test
(for information request and reply).

•

UDP ports 7 (slave UDP port) and 7777 (master UDP port)
needs to be vacated for the network-under-test.

•

During an RFC2544 test, the FrameScope Pro has a default
timeout duration after a MAC reset. If the peer does not
respond within the stipulated time, the RFC 2544 test will
not start and will result in a timeout. Different switches may
have different response times after a MAC reset. You should
select a suitable and appropriate timeout period for the
switches-under-test with reference to the equipment
requirements as supplied by the supplier or vendor.