Agilent Technologies N2620A User Manual
Page 77

Network Testing with the FrameScope Pro
2
N2620A User’s Guide
59
Frame loss rate settings screen
Specify the frame length or
select Full Range to collect all
frames
For full duplex networks, you can
specify bidirectional testing.
For half duplex networks, upstream
and downstream can be tested
sequentially.
Select the frame direction to
measure (bidirectional is only
present for loopback)
Max Data Rate is used for initial
frame speed and performance
calculation. Enter the maximum data
rate of the network-under-test. If the
maximum data rate is unknown, the
link speed will be used.
Duration is the time taken (in seconds)
to transmit frames. For better results,
adjust the duration to load the
device-under-test sufficiently.
Select Full Range to measure
the frame loss rate specified
by the step size, or type in a
specific rate