Error code (SSB2)

The pair cannot be created because the status of the configuration could not be transited.

8F53

The pair cannot be created or resynchronized because of the one of following reasons.

8F58

The pair status of the specified S-VOL differed from the one of P-VOL.

The state of restore journal differed from the state of master journal.

The pair cannot be created because the specified secondary system did not support the external
volume.

8F67

The pair cannot be created because the specified volume was a command device.

8F6D

The pair cannot be created because the P-VOL is used for Fast Snap.

8FEA

The pair cannot be created because the P-VOL is used for Fast Snap.

8FEC

The command cannot be executed because user authentication is not performed.

9100

The required shared memory for operating Cnt Ac-J Z is not installed

B91C

The information of the consistency group cannot be retrieved, because Continuous Access Journal
Z was not installed.

B992

The source of command devise has run out. Set to OFF the command device and to ON again
from the LUN Manager.

B9C0

RAID Manager error codes for Cnt Ac-J Z: SSB1 = B9E1

Description

Error code (SSB2)

The command was rejected because the specified device is a command device.

B901

RAID Manager error codes for Cnt Ac-J Z: SSB1 = B901, B9E0, B9E1, B9E2,
B9E4, D004

Description

Error code (SSB2)

The command was rejected because the mirror ID is invalid.

B902

The command was rejected because the volume was unpaired.

B907

The S-VOL hide mode is not supported.

B90A

The command was rejected because the Cnt Ac-J Z program product is not installed.

B90D

The command was rejected because the mirror ID is invalid.

B909

A status of Cnt Ac-J Z pair was acquired at the time of unavailable to use the Cnt Ac-J Z during
the power-on. Retry the operation.

B900

The command was rejected because the Cnt Ac-J Z configuration was changed. Check the status
of the Cnt Ac-J Z pair.

B94B

The command was rejected because the path is not set between the systems.

B90E

A request for a Cnt Ac-J Z Paircreate operation was rejected because neither Cnt Ac-J Z nor Cnt
Ac-S Z was installed.

B90F

The settings of the journal option could not be updated.

B910

The command was rejected because the system configuration does not allow these operations.

B913

The command was rejected because no journal was registered.

B912/B9F8

The pair cannot be created because the system identifier is not correct (left-most number in the
6-digit serial number).

B920