HP XP7 Storage User Manual

Page 130

Advertising
background image

Continuous Access Journal Z SIMs are displayed in the Remote Web Console Status window.

SIMs generated by the primary system include the P-VOL device ID (byte 13).

SIMs generated by the secondary system include the S-VOL device ID (byte 13).

The figure below shows a typical 32-byte SIM from the system. The six-digit reference code consists
of bytes 22, 23, and 13. The reference code identifies the possible error and determines the
severity. The SIM type (byte 28) indicates the component that experienced the error. When the
value of byte 22 is 21, the SIM is a control unit SIM. When the value of byte 22 is Dx (where x
is an arbitrary character), the SIM is a device SIM.

Figure 17 Typical SIM with reference code and SIM type

The following table shows SIM reference codes, and provides useful information for identifying
issues and determining the system experiencing the problem. All SIMs are reported to the host,
except 21 80, 21 81, and possibly DC EX—depending on the value set for system option mode
598. For more information, see

“System option modes ” (page 37)

.

SVP log file

System generating the
SIM

Description

Severity

Reference code

Byte 23

Byte 22

SIM Log

Local/Remote

A remote path is blocked due to failure.

Moderate

80

21

SSB Log

Local/Remote

The remote path is restored.

Service

81

21

SIM Log

Local/Remote

A line failure is reported by the extender.

Moderate

82

21

SIM Log

Local

The P-VOL has been suspended.

Serious

0X

DC

Path recovery is impossible.

SIM Log

Local

The P-VOL has been suspended.

Serious

1X

DC

A failure has been detected in the primary
system.

SIM Log

Local

The P-VOL has been suspended.

Serious

2X

DC

A failure has been detected in the
secondary system.

SIM Log

Local

The P-VOL has been suspended.

Serious

4X

DC

The pair has been suspended at the
secondary system.

SIM Log

Local

The P-VOL has been suspended.

Serious

5X

DC

A pair has been released at the
secondary system.

SIM Log

Local

The S-VOL has been suspended.

Serious

6X

DC

Path recovery is impossible.

SIM Log

Remote

The S-VOL has been suspended.

Serious

7X

DC

A failure has been detected in the
secondary system.

130 Cnt Ac-J Z troubleshooting