Restoring journals manually, When the error is in the local system, When the error is in the remote system – HP XP7 Storage User Manual

Page 59

Advertising
background image

Figure 16 Journals that can be registered when P9500 or XP24000/XP20000 Disk Array is the
supervisor DKC

Restoring journals manually

Normally, Cnt Ac-J Z restores journals within EXCTGs. However, when an error occurs, manual
restoration is necessary. The method for restoration differs according to whether the error occurs
in the local or remote storage system.

When the error is in the local system

If an error occurs in a local storage system, restore joiurnal data to the S-VOL with timestamps later
than the EXCTG’s consistency time. In the

Figure 13 (page 50)

example, EXCTG consistency time

is 15:00. In this example, you must restore the following data to the S-VOLs:

Data with time stamp 15:02 in journal 2

Data with time stamp 15:03 in journal 3

Data with time stamp 15:04 in journal 4

To manually restore data to the S-VOLs, specify a journal ID with the BCM command, YKRESYNC,
and resynchronize all pairs in the specified journal collectively (see

“Splitting, restoring, releasing

pairs in an EXCTG ” (page 55)

).

When the error is in the remote system

If an error occurs in a remote storage system, compare consistency times of all journals in the
EXCTG, then restore joiurnal data to the S-VOL with timestamps later than the EXCTG’s consistency

Restoring journals manually

59