HP XP7 Storage User Manual

Page 60

Advertising
background image

time. In the

Figure 13 (page 50)

example, journal 2 has the oldest timestamp, 14:02. Therefore,

you must restore the following data to the S-VOLs:

Data with time stamp 15:00 in journal 1

Data with time stamp 15:02 in journal 2

Data with time stamps 14:03 and 15:03 in journal 3

Data with time stamps 14:04 and 15:04 in journal 4

To manually restore data to the S-VOLs, specify a journal ID with the BCM command, YKRESYNC,
and resynchronize all pairs in the specified journal collectively (see

“Splitting, restoring, releasing

pairs in an EXCTG ” (page 55)

).

60

Using extended consistency groups

Advertising