time. In the
example, journal 2 has the oldest timestamp, 14:02. Therefore,
you must restore the following data to the S-VOLs:
•
Data with time stamp 15:00 in journal 1
•
Data with time stamp 15:02 in journal 2
•
Data with time stamps 14:03 and 15:03 in journal 3
•
Data with time stamps 14:04 and 15:04 in journal 4
To manually restore data to the S-VOLs, specify a journal ID with the BCM command, YKRESYNC,
and resynchronize all pairs in the specified journal collectively (see
“Splitting, restoring, releasing
).
60
Using extended consistency groups
Advertising