ENG

Replace worn or damaged components with genuine Bondioli & Pavesi spa-

re parts. Do not modify or tamper with any part of the driveline. For any

operations not explained in this instruction manual, consult your local Bondioli &

Pavesi representative.

Check that all components are in good condition and properly lubricated

before using the driveline. Clean and re-lubricate the driveline before sea-

sonal storage.

Lubricate each part after the number of hours shown in chart.

Heavy duty applications in aggressive environments may require more

frequent lubrication intervals.

The quantitiv of grease specified in the manual is recommended for intervals of

50 hours.

Quantities specified in grams (g). 1 ounce (oz.) = 28.3 g (grams).

Inject grease into the cross kit until it purges from each bearing cap.

Pump progressively and avoid high pressures from the grease gun

Recommended grease NLGI 2.

Following seasonal use, it is recommended to clean out any grease inside the CV

shield.

TORQUE LIMITER AND OVERRUNNING CLUTCH

RA - RL OVERRUNNING CLUTCHES

This device prevents transmission of inertial loads from implement to the

tractor during deceleration or stopping of the PTO.

Lubricate every 50 hours of use and after storage.

The RL overrunning clutches do not require lubrication and are not equipped

with grease fittings.

Keep clear of the machine until all parts have stopped moving.

SA - LC RATCHET TORQUE LIMITERS

This device interrupts the transmission of power when the torque exceeds

the setting.

Immediately disengage the PTO when ratcheting sounds are heard.

Lubricate every 50 hours of use and after storage.

The LC limiters are fitted with seal rings and require lubricaion only once each

season.

LN - LT SYMMETRICAL RATCHET TORQUE LIMITERS

This device interrupts the transmission of power when the torque exceeds

the setting.

Immediately disengage the PTO when ratcheting sounds are heard.

Lubricate every 50 hours of use and after storage.

The LT limiters are fitted with seal rings and require lubricaion only once each

season.

LB – SHEAR BOLT TORQUE LIMITER

This device interrupts the transmission of power by shearing a bolt when the

torque exceeds the setting.

Replace the sheared bolt with the same diameter, length and grade as the original.

Lubricate the LB limiters with grease fittings at least once every season and after

long periods of storage.