9-6

-

brd_cfg -w board 00 02 24 02

DSP write

-

tx: 80000001

DSP read

-

rx: ef000020

9.2.4.2 Menu Items

By right-clicking on the “Log” window, a menu is shown with the following options:

Save As–Save the log as a text file for later viewing.

Save As *.cfg–Save as a DSP configuration file. The configuration file includes all the writes since
the last reset.

Copy–Copies the selection to the clipboard.

Select All–Select all of the text in the log file.

Clear–Clears the “Log” window text.

9.2.5 Source Selection Group

The Source Selection Group allows the user to select which source is active on the board. When the
connection is in JP1 mode, this group is disabled.

Figure 9-10. DSP Condenser Runtime Source Selection Group

9.2.5.1 Input Source Combo Box

The following input source exists:

9.2.5.2 Apply Button

The “Apply” button configures the board so the input source selected in

Table 9-1

is used.

9.2.5.3 Reset DSP When Changing Source Checkbox

When the “Reset DSP When Changing Source” box is checked, the DSP is reset after the board is
programmed to handle a new source.

Table 9-1. Translation from Input Sources to Board Configuration Values

Input Source

Board Configuration Value

S/PDIF RX0 1 fs

00 02 24 02 00

S/PDIF RX1 1 fs

02 02 24 02 00

HDMI Legacy

06 03 24 02 00

HDMI PCM 2 fs

06 42 24 12 00

HDMI PCM 4 fs

06 81 24 02 00

ADC Stereo