AT&T 2400 User Manual

Page 103

Advertising
background image

Issue 2 December 1995

8-15

Setting a Security Level

The factory sets the SID to access level 1. When you first power on the SID, the
unit accesses the SETUP menu and allows you to access all tools required to
perform the administration tasks. You can select a security level for the SID and
make the security level part of the configuration. AT&T recommends that you
select security level 0 as the normal operating mode for the SID. Users only can
access level 0 features, which reduces the risk of tampering by unauthorized
users.

Use the following instructions to set the security level on the SID.

1. Press

to

access the MAIN menu as shown in the following

example:

2. Press

to select the UTILS menu as shown in the following example:

3. Press

to select the LOGIN form as shown in the following example:

4. Press the arrow (< - ->) keys to change the access level to 0.

5. Press

to

save

the

change.

The SID immediately updates your

security level.

To log in to level 1, use the instructions above to access the LOGIN form. Use the
arrow keys to set Access Level to 1. The SID now asks you for a password. Type
in the level 1 password and press

.

NOTE:

As you type the password, you do not see the letters on the screen.

When you complete the instructions in this chapter, proceed to Chapter 9,
"Acceptance Tests", in
this document.

NEC

1-View

2-Utils

3-System

4-Setup

5-Logs

UTILS

1-Login

2-Date/Time

3-Serial

LOGIN

Access Level:

1

<- ->0

Password

FUNC

2

1

ENTER

ENTER

Advertising