Introduction and Requirements for Integration

In addition to the hardware and software listed in Table 1-3, you must provide the
following administration on the NEAX 2400.

Program the PA-16LCQ analog ports to provide an adequate loop current
disconnect, or

wink. The PA-16LCQ card provides a default value of

approximately 128ms wink. The wink can be increased to approximately
448ms with a firmware upgrade from NEC. Without the upgrade and the
increase, two items occur:

— Call holding times increase substantially because the default

disconnect time is lower than the minimum time required by the
INTUITY System.

— Call answer messages end with a reorder tone of approximately

one second.

Set the recall timer on the NEAX switch to an amount of time longer than
the ring-no-answer time. If you do not, calls blind transferred to
subscribers administered for

forward on ring-no-answer recall back to the

INTUITY System channel.

Administer the INTUITY System to transfer calls to a station other than an
actual attendant console, for example a digital telephone capable of
displaying calling party information. The NEAX 2400 switch does not allow
stations to transfer calls to an attendant console.