Switch Integration Device Problems

The SID does not power on.

Nothing appears on the LCD display.

Calls are not integrated.

Possible Reason:

The power cord connection may be loose or not
completed.

Remedy:

Make sure the power cord is firmly plugged into the
wall outlet and the SID.

Possible Reason:

The wall outlet may not have power.

Remedy:

Make sure the circuit breaker for the wall outlet is on.

Possible Reason:

The SID power switch may be set to the

OFF position.

Remedy:

Turn the SID power switch to the

ON position.

Possible Reason:

The SID may have a bad fuse.

Remedy:

Check the fuse on the SID.

Possible Reason:

You may need to adjust the LCD contrast.

Remedy:

Refer to Chapter 8, "Swi tch Integrat ion Device
Administration" for inst
ructions on adjusting the LCD
contrast.

Possible Reason:

The cables between the SID and the INTUITY System
may not be connected correctly.

Remedy:

Refer to Chapter 4, "Hardware Installation", and check
the cable connections.

Possible Reason:

The INTUITY System may not be administered
correctly.

Remedy:

Check the administration of the system using Chapter 6
of this document.

Possible Reason:

The SID may be administered incorrectly.

Remedy:

Refer to Chapter 8, "Switch Integration Device
Administration", a
nd check the administration of the
system. Make sure the channels and extensions are
configured correctly.

Possible Reason:

The baud rate for the SID-to-INTUITY System
connection may not be set correctly.