AT&T 2400 User Manual

Page 64

Advertising
background image

6-4

Issue 2 December 1995

Administering the INTUITY System for the NEAX Integration

Table 6-1.

Switch Link Administration Screen Entries

Field

Description

Data link test
number

Indicates the test number sent to the switch to verify
whether the switch is active.

Setting: A 7- or 10-digit number that is

not an in-

service extension number. The number of digits must
agree with the setting for the dialstring size set on the
SID. Refer to Chapter 3, "Switch Integration Planning",
to find the dialstring size.

Serial port

Indicates which port on the multi-port circuit card in the
INTUITY system is connected to the integration device.

Setting: Press

(F2) to choose from a menu of

available ports. Settings are in the format /dev/ttysa

x,

where

x is a letter a - h representing a port on the

circuit card (from right to left). AT&T recommends that
you use /dev/ttysaa as the serial port.

Baud rate

Indicates the rate at which the SID and the INTUITY
system communicate.

Setting: A baud rate of 1200, 2400, 4800, or 9600.
Press

(F2) to choose from a menu of possible

settings. This setting must agree the BAUD setting on
the SID. AT&T recommends that you use a baud rate
of 2400.

Comment

Use the field to enter a comment. Enter a maximum of
30 characters. In your comment, do not use double
quotation marks (“) or

+ backslash (\).

CHOICES