AT&T 2400 User Manual

Page 74

Advertising
background image

7-4

Issue 2 December 1995

NEAX 2400 Switch Administration

4. Enter 1 to select the Assignment of Station Data option and enter station

administration information for each voice mail port. After you select the
option, you see the screen as shown in Figure 7-3.

Figure 7-3. Assignment of Station Data Screen

5. In the TN (Tenant Number) field, you see a default value of 1. To select the

default value, press .

The

cursor moves to the STN field.

Contact your switch system administrator to determine if this value must
be modified.

6. At the STN (station) field, enter the number you plan to use as an analog

voice mail port extension. After you press

the

cursor

moves to the

LENS field.

For example, if you want to assign extensions 500, 501, 502, and 503 to a
four port system, enter 500 as the first extension.

7. In the LENS (Line Equipment Number) field, you see a default value of

00000. Enter the correct LENS. After you press

the cursor moves to

the TEC field.

Contact your switch system administrator for the correct line equipment
assignment.

8. In the TEC (Telephone Class) field, you see a default value of 1. Enter 3 in

the field to permit dial pulse and push button functionality. After you press

the cursor moves to RSC field.

Assignment of Station Data

TN: 1 STN: TN : Tenant Number

LENS: 000000 STN : Station Number

TEC: 1 RSC: 0 SFC: 0 LENS: Line Equipment Number (6 Digits)

TEC : Telephone Class (1-31)

1-DP (10PPS) 22-EMM

2-PB

3-DP/PB

11-VMM/VMZ

12-Dterm V

13-Data Terminal via Dterm V

14-Hot Line

15-Cas Line

RSC: Route Restriction Class (0-15) 16-Data Terminal via Data Module

for assignment of RSC,ARSC cmnd 18-Virtual Line Appearance

SFC: Service Feature Class (0-15) 19-TMM

for assignment of SFC,ASFC cmnd 20-PSM

ENTER

ENTER

ENTER

ENTER