AT&T 2400 User Manual

Page 58

Advertising
background image

5-6

Issue 2 December 1995

Installing SID Software on the INTUITY System

Table 5-1.

Switch Link Administration Screen Entries

Field

Description

Data link test number

Indicates the test number sent to the switch to verify
whether the switch is active.

Setting: A 7- or 10-digit number that is

not an in-

service extension number. The number of digits must
agree with the setting for the dialstring size set on the
SID. Refer to Chapter 3, "Switch Integration Planning",
to find the dialstring size.

Serial port

Indicates which port on the multi-port circuit card in
the INTUITY system is connected to the integration
device.

Setting: Press

(F2) to choose from a menu of

available ports. Settings are in the format /dev/ttysa

x,

where

x is a letter a - h representing a port on the

circuit card (from right to left). AT&T recommends
that you use /dev/ttysaa as the serial port.

Baud rate

Indicates the rate at which the SID and the INTUITY
system communicate.

Setting: A baud rate of 1200, 2400, 4800, or 9600.
Press

(F2)

to

choose

from a menu of

possible settings. This setting must agree the BAUD
setting on the SID. AT&T recommends that you use a
baud rate of 2400.

Comment

Use the field to enter a comment. Enter a maximum of
30 characters. In your comment, do not use double
quotation marks (“) or

+

backsl

ash (\).

CHOICES

CHOICES

SHIFT

Advertising