I N S T A L L A T I O N

Shared System 25 Voice/STARLAN NETWORK

Data

Connections

STARLAN NETWORK workstations can share the 4-pair System 25 wiring to

the SIP with an analog or 7300H Series voice terminal. The STARLAN

NETWORK data is transmitted over pairs two and three. At the SIP, the data
pairs and voice pair(s) are

separated by the standard Y-adapter

(WP90851 ,L1 ). The data pairs are connected to the STAR LAN NETWORK

NEU. For analog single-line voice terminals, the voice pair is connected by

an octopus cable to a ZTN78 CP. For 7300H Series voice terminals, the
voice pairs are connected to a ZTN79 CP. A KS-23475, L1 Adapter and a

KS-2291 1 Power Unit are also required at the workstation to provide power

to the 7300H Series voice terminal.

Single-Line Voice Terminals

See Figure 2-50.

1.

Unpack each terminal and examine it for damage.

2. At the workstation, connect one end of the terminal line cord to the

terminal and the other end to the PHONE jack on the NAU.

3. Using a D8W-87 modular cord, connect the OUT jack on the NAU to

the modular wall jack.

4 .

Locate the workstation appearance at the SIP, and disconnect the

octopus cable. Install a WP90581, L1 Y
octopus cable plug to the VOICE jack.

5. Using a D8W-87 modular cord, connect

Adapter to the STARLAN NETWORK NEU

Adapter, and connect the

the DATA jack on the Y
IN jack.

2-113