Connection to ztn76 or ztn77 cp – AT&T System 25 User Manual

Page 157

Advertising
background image

INSTALLATION

Connection to ZTN76 or ZTN77 CP

PagePac 20 system with ZoneMate 9/39 and Common Control Unit (CCU)
provides up to nine/thirty-nine paging zones and multizone groups.

To connect a PagePac 20 system, make connections using the following

steps (Figure 2-58):

1.

2.

3.

4.

5.

6.

7.

Place the PagePac amplifier on the ZoneMate and the CCU.

Connect the three units as follows:

a .

Plug the cord attached to the CCU into the modular jack on

the PagePac system.

b. Connect the 25-pin cable between the ZoneMate and the

C C U .

c .

Plug GR Molex connector from CCU into PagePac 20.

Using a D4BU modular cord connect the jack on the back of the

CCU to the 103A connecting block.

Using 4-pair inside wiring cable, connect the 103A connecting block

to the TAE 700A block. Make the following connections:

700A Block Term.

103A Term.

T

1

R

2

Attach the speakers to the ZoneMate.

Set the switch on the CCU to LS for loop-start trunks or GS for
ground-start trunks.

For ground start trunks, connect the black lead from the 2-pair cord

supplied with PagePac 20 to the System 25 cabinet ground block.

2-128

Advertising