MAINTENANCE

Error records in the Most Recent System Errors table have a slightly different

format. A typical error record from the Most Recent System Errors table is

MOST RECENT SYSTEM ERRORS

P O R T

BOARD DATE

TIME

N A M E

NUMBER CODE

OCCURRED OCCURRED

30300

ZTN131 03/12/85

2:01:56

Port Board Missing

But Administered

Interpret this record as follows:

“Port Number” 30300 is the 5-digit port identification number.

“Board Code” ZTN131 is the circuit pack on which the error

occurred (or that is associated with the error if this is an off-board
error).

“Date Occurred” 03/1 2/85 is the date this error occurred. A

conventional calendar designation is used.

“Time Occurred” 12:01:56 is the time this error occurred. A 24-hour

clock is used.

“Name” Port Board Missing But Administered is a description of the

nature of the error.

A combined total of 40” (R1V1 ) or 50” (RIV2, R2V1, R3) error records for

Permanent System Alarms and Transient System Errors is stored by the

system. Ten error records are stored in the Most Recent System Errors

table. Errors are displayed in the order that they occurred.

Two or more instances of the same error result in only two entries in the log (that is, the first
and last occurrence).

4-29