INSTALLATION

Make

SIP

Connections to Cabinet for MET Sets

Follow the same procedure as for 7300H Series terminals to connect MET set

SIP appearances to the appropriate CPs as outlined below:

Note:

Connect the 25-pair connector to a TN735 CP

Attach a cable label to the octopus cable 25-pair connector and flag-

type tie wrap

Run the cable 10 the 50A Fanning Strip

Plug cable ends into the appropriate SIP adapters

Complete the Voice and Data Station Records Form.

Each TN735 CP supports only four MET sets. Therefore, only the first

four modular plugs on each octopus cable should be connected to the

SIP adapters.

Make SIP Connections to Cabinet for Single-Line Sets

Follow the same procedure as for 7300H Series terminals to conned single-line

voice terminal SIP appearances to the appropriate CPs as outlined below:

Connect the 25-pair connector of the octopus cable to a ZTN78 CP

Attach a cable label to the octopus cable 25-pair connector and flagtype

tie wrap

Run the cable to the 50A Fanning Strip

Plug the cable ends into the appropriate
Voice and Data Station Records Form.

For extended, off-premises, and out of-building

adapters, and complete the

stations, follow the same

procedure as above, except connect the octopus cable to a TN742/TN746 CP.

For Connection to a TN746 CP, follow the procedure outlined below.

Attach the connector marked “0’ of the 853B adapter to a TN746 CP

("0")

2-74