Direct connection to tn763 auxiliary trunk cp – AT&T System 25 User Manual

Page 149

Advertising
background image

INSTALLATION

Direct Connection to TN763 Auxiliary Trunk CP

Paging

( F i g u r e

equipment can be connected directly to a TN763 Auxiliary Trunk CP

2-55) when the following conditions exist:

Paging equipment is FCC registered.

Paging equipment requires a contact closure

Connect as shown in Figure 2-55, following the steps

1.

Connect the CP to a 66-type block, using
Use kit-of-parts D-1 81524 (PEC 62511).

N o t e : The 66-block provides a 3-pair

for proper operation.

below:

an A25D 25-pair cable.

interface to TN763

(see Appendix A of this manual for details).

2.

Using 4-pair inside wiring cable, connect the 66-block to a 103A

connecting block. Make the following connections:

66-Block Term.*

103A Term.

T

1

R

2

SZ

3

SZl

4

s

5

S1

6

*

T,R is the voice pair; SZ,SZ1 is the seizure request pair; and S,S1

is the seizure acknowledge pair to the TN763.

3.

Using a D4BU cord, connect the paging equipment to the 103A
b l o c k .

4.

If you are installing a PagePac 20 system, connect the speakers to

the receptacle on the back of the PagePac system.

2-122