Data Line Troubles

Symptoms:

Data terminals connected through the Data Line CP (TN726) are dead

or are not functioning properly.

Procedures:

1.

Check that the RS-232C connector on the Asynchronous Data Unit

(ADU) is properly connected to the RS-232C connector on the data

terminal. Always tighten connector screws and fasteners.

2. Check the terminal ac power connection.

3. Make sure that the connection to the ADU is a 4-pair modular plug.

4. Check the ADU ac power connection (see Steps 5, 6, and 7). An ADU

connected to a port on the CPU/Memory CP must have a local ac power
source. Briefly disconnect the ADU’s power cord.

5. If the ADU is not externally powered, check pin 20 (DTR signal on the

RS-232C connector) for presence of at least +7 volts relative to pin 7
(ground).