MAINTENANCE

N o t e : For problems with administration equipment that is not

connected on a dedicated basis, refer to the Terminal
Operations Manual, 555-540-710.

Time-Keeping Troubles

Symptoms:

Clock

Procedures:

1.

Reset

doesn’t reflect current time or date.

clock from SAT (see the Administration Manual). Clock has

tolerance of plus or minus 3 minutes per month. Variances outside
this range indicate a faulty clock and require replacement of the
CPU/Memory CP. Time must be reset

Voice Terminal and Wiring Troubles

Symptoms:

Intermittent voice terminal troubles.

Procedures:

1.

2.

3.

4.

5.

Swap a known good terminal with

for Daylight Savings Time.

the questionable terminal to

determine if problem is localized to a single terminal. If local power
is provided, check power supply.

if troubles do not persist, problem is localized to single terminal.
Replace faulty terminal.

If good terminal does not work properly, fault is in wiring or circuit

pack (CP).

Check other terminals connected to same CP. If other terminals are
working properly, fault is probably in wiring. Swap wiring between
Station Interconnect Panel and terminal to verify wiring problem.
Check and clear any wiring problems.

If other terminals connected to same CP are not working properly,

fault is probably in CP.

4-82