APPENDIX C: System Additions or Changes

Add Terminal

1.

2.

3.

4.

5.

6.

Evaluate the cabinet unit power load using the procedures under
“Evaluate cabinet unit Power Load” in this appendix.

Check for available ports on

checking the octopus cables
the back of the cabinet.

a compatible CP using the SAT or by
attached to the 25-pair receptacles on

the building wiring from the terminal to

If a port is available, connect

an unused termination on the SIP, following the instructions under

“connect Cabinets to SIP” in Section 2. Then, insert plug on the

octopus cable into the modular jack.

If a port is not available, add the correct CP and octopus cable,

following the procedures under “Add Circuit Pack” in this appendix.
Then connect the building wiring from the terminal to a termination
on the SIP, following the procedures under “Install Cross-Connect

Equipment” in Section 2. Next, connect the new CP to the SIP with

an octopus cable, following the procedures under “Connect Cabinets
to SIP” in Section 2.

Finally, install the terminal, following the

procedures under “Install Terminals” in Section 2.

Follow standard procedures for translating the terminal port using

the SAT.

Document the new terminal on the Voice and Data Station Records
Form.