Connection to tn763 auxiliary trunk cp (278a, Adapter required) – AT&T System 25 User Manual

Page 151

Advertising
background image

INSTALLATION

Connection to TN763 Auxiliary Trunk CP (278A Adapter
Required)

A 278A Adapter is required to connect paging equipment to a TN763 Auxiliary

Trunk CP (Figure 2-56) when the following conditions

l Paging equipment is not FCC registered.

l Paging equipment requires a contact closure

Connect as shown in Figure 2-56, following the steps

1.

2.

3.

4.

Connect the CP to a 66-type block, using
Use kit-of-parts D-1 81524 (PEC 6251 1).

Note:

The 66-block provides a 3-pair

e x i s t :

for proper operation.

below:

an A25D 25-pair cable.

interface to TN763

(see Appendix A of this manual for details).

Using 4-pair inside wiring cable,

66-type block to a 278A adapter.

CP Leads*

T
R

S Z

SZl

S

S 1

l T,R is the voice pair; SZ,SZ1 is
is the seizure acknowledge pair.

connect the following leads on the

278A Term.

T
R

B Z 1

G R D

B Y 1
B Y 2

the seizure request pair; and S,S1

Open the 278A adapter, and install a strap between terminals BZ2
and -V.

Move the yellow shorting plugs so that the following connections are

made (Figure 2-57).

A to B

E to F

G to H

D to C and J to K should be open.

2-124