10. Settings

An alternative to a full screen White/black pattern is the standard gray scale pattern, the white bar will be used
for white balance and the black bar for black balance.

Image 10-24

Black balance

1. Press MENU to activate the Toolbar

2. Press → to select the Image item

3. Press ↓ to Pull down the Image menu

4. Use ↑ or ↓ to select Input balance

5. Press → to pull down the menu

6. Use ↓ or ↑ to select Black balance (image 10-25)

7. adjust the red black level on a minimal value (image 10-26, image 10-27)

8. adjust the blue black level on a minimal value

Note:

this minimal value is not necessary , provided that the 2 other colors are not influencing too much the color to be adjusted,
in fact the aim is to minimize the effect of the two other colors since there is a risk of reaching too soon the transition due
to the contribution of these two other color signals.

9. Adjust the green black level until bright spots appear on the screen

10.adjust the blue black level on a minimal value

Note:

this minimal value is not necessary , provided that the 2 other colors are not influencing too much the color to be adjusted,
in fact the aim is to minimize the effect of the two other colors since there is a risk of reaching too soon the transition due
to the contribution of these two other color signals.

11.Adjust the green black level until bright spots appear on the screen

12.Adjust the Blue black level until bright spots appear on the screen

13.Adjust the red black level until bright spots appear on the screen

The projected image should know be noisy full black