Fig. 74 -- Outdoor--Air Damper Leakage

Differential Dry Bulb Control
For differential dry bulb control the standard outdoor dry

bulb sensor is used in conjunction with an additional

accessory

dry

bulb

sensor

(part

number

CRTEMPSN002A00). The accessory sensor must be

mounted in the return airstream. (See Fig. 75.) Wiring is

provided in the EconoMi$er IV wiring harness.
Outdoor Enthalpy Changeover
For enthalpy control, accessory enthalpy sensor (part

number HH57AC078) is required. Replace the standard

outdoor dry bulb temperature sensor with the accessory

enthalpy sensor in the same mounting location. (See

Fig. 66.) When the outdoor air enthalpy rises above the

outdoor enthalpy changeover setpoint, the outdoor-air

damper moves to its minimum position. The outdoor

enthalpy changeover setpoint is set with the outdoor

enthalpy setpoint potentiometer on the EconoMi$er IV

controller. The setpoints are A, B, C, and D. (See Fig. 76.)

The factory-installed 620-ohm jumper must be in place

across terminals S

R

and SR+ on the EconoMi$er IV

controller (see Fig. 68).
In this mode of operation, the outdoor-air temperature is

compared to the return-air temperature and the lower

temperature airstream is used for cooling. When using this

mode of changeover control, turn the enthalpy setpoint

potentiometer fully clockwise to the D setting. (See

Fig. 72.)

ECONOMI$ERIV

ECONOMI$ERIV
CONTROLLER

GROMMET

RETURN AIR
SENSOR

RETURN DUCT
(FIELD-PROVIDED)

C07085

Fig. 75 -- Return Air Temperature or Enthalpy Sensor

Mounting Location

CONTROL

CURVE

A
B
C
D

CONTROL POINT

APPROX.

deg. F (deg. C)

AT 50% RH

73 (23)
70 (21)
67 (19)
63 (17)

12

1

4

1

6

18

20

2

2

24

26

28

30

32

3

4

36

38

40

42

44

46

90

10

0

80

70

60

50

40

30

20

10

ENTHALPY BTU PER POUND DRY AIR

85

(29)

90

(32)

95

(35)

100

(38)

105

(41)

110

(43)

35

(2)

35

(2)

40

(4)

40

(4)

105

(41)

110

(43)

45

(7)

45

(7)

50

(10)

50

(10)

55

(13)

55

(13)

60

(16)

60

(16)

65

(18)

65

(18)

70

(21)

70

(21)

75

(24)

75

(24)

80

(27)

80

(27)

85

(29)

90

(32)

95

(35)

100

(38)

A

A

B

B

C

C

D

D

RELATIVE HUMIDITY (%)

HIGH LIMIT

CURVE

APPROXIMATE DRY BULB TEMPERATURE--degrees F (degrees C)

C06037

Fig. 76 -- Enthalpy Changeover Setpoints