30 @aare – B&B Electronics Network Device I-7011 User Manual
Page 52
Advertising
![background image](/manuals/53852/52/background.png)
52
I-7011, I-7018 User Manual
Rev:B1.0
2.30 @AARE
Description : Read Event Counter
Syntax : @AARE[CHK](cr)
@
delimiter character
AA
address of reading module (00 to FF)
RE
command for reading event counter
Response :
Valid Command :
!AA(Data)[CHK](cr)
Invalid Command :
?AA[CHK](cr)
Syntax error or communication error may get no re-
sponse.
!
delimiter for valid command
?
delimiter for invalid command
AA
address of response module(00 to FF)
(Data)
event counter value, from 00000 to 65535.
Example :
Command : @01RE
Receive : !0101234
Read address 01 event counter, return 1234.
Related Command :
Sec.2.31 @AACE
Related Topic :
Sec.3.4 Digital Input and Event Counter
Note : The command is for I-7011/11D/11P/11PD only