Brocade Communications Systems Brocade MLX Series and Brocade Netlron XMR 53-1002373-02 User Manual

Page 251

Advertising
background image

Brocade MLX Series and Brocade NetIron XMR Hardware Installation Guide

233

53-1002373-02

Verifying proper operation

3

Syntax: show module

The Status column shows the module status. The management module status can be one of the
following:

ACTIVE – The module is currently the active management module.

STANDBY – The module is currently the standby management module.

COMING UP – The module is coming up as the standby module. This status occurs if the
standby management module becomes the active module during a switchover.

The switch fabric module status can be one of the following:

ACTIVE – The module is up and running.

BAD – The management module cannot initialize the switch fabric module.

An interface module status can be one of the following:

CARD_STATE_INIT – The system detects the module but the module is not up and running yet.

CARD_STATE_BOOT – The module is booting.

CARD_STATE_INTERACTIVE – The module is booting from interactive mode.

CARD_STATE_LP_SYNC – The software images are synchronized between the management
module and interface module.

CARD_STATE_SYNC – The system is currently synchronizing the software image between the
management module and interface module.

CARD_STATE_SOFTWARE_LOADED – The module has loaded the software image.

CARD_STATE_POWER_OFF – The module does not have power.

CARD_STATE_UP – The module is operating normally.

CARD_STATE_FAILED – The management module was unable to bring up an interface module.
If you see this status, make certain that the interface module is installed properly. For more
information, refer to

“Installing Brocade MLX-4 modules”

on page 158,

“Installing Brocade

MLX-8 modules”

on page 167,

“Installing Brocade MLX-16 router modules”

on page 178, or

“Installing Brocade MLX-32 router modules”

on page 209.

CARD_DOWN_REASON_<explanation> – The module is in a nonfunctional state. This status
appears with an explanation for why the module is down. For example,
"CARD_DOWN_REASON_BOOT_FAILED.” If the explanation does not help you resolve the
problem, contact technical support and provide the explanation included with this status.

Brocade# show module

Module Status Ports Starting MAC

M1 (upper): Brocade router Mgmt Module Active

M2 (lower):

F0: Brocade router Switch Fabric Module Active

S1:

S2:

S3:

S4: Brocade router 4-Port 10Gig Module CARD_STATE_UP 4 000c.db80.0000

S5: Brocade router 4-Port 10Gig Module CARD_STATE_UP 4 000c.db80.0000

S6: Brocade router 4-Port 10Gig Module CARD_STATE_UP 4 000c.db80.0000