26

Brocade MLX Series and Brocade NetIron XMR Hardware Installation Guide

53-1002373-02

Router modules

1

CFP optics

The 100 GbE interface module is 802.3ba compliant, supports CFP-based optics, and is
backwards-compatible with existing Brocade MLX and Brocade NetIron XMR interface modules.
This interface module requires high-speed fabric modules. 100GbE interface modules will boot in
turbo mode if all modules in the chassis are Gen-2 modules.

You must insert CFP-compliant fiber-optic transceivers in each port you intend to use.
CFP-compliant transceivers provide an optical or physical medium-dependent (PMD) interface for
single- or multi-mode fiber that can be used with either the LAN physical layer (PHY) or WAN
physical layer (WAN PHY).

For a list of supported 100xGbE CFP-compliant fiber-optic transceivers that are available from
Brocade, refer to the latest version of the Brocade Optics Family Data Sheet, available online in the
following location:

http://www.brocade.com/downloads/documents/data_sheets/product_data_sheets/Optics_DS.p
df

For more information about fiber-optic transceivers and associated cabling, refer to

“Installing a

fiber-optic transceiver”

on page 318.

Power supply requirements for 100xGbE modules

Table 6

lists the power supply requirements for each type of router when installing 100xGbE

modules.

TABLE 6

Power supply requirements for 100xGbE modules

Router type

Number of 100xGbE
modules installed

Power supply requirements (minimum required-redundancy requirements)

MLXe-4

one

one 1200W PSU
for 1+1 redundancy, install two 1200W PSU

one 1800W PSU
for 1+1 redundancy, install two 1800W PSU

two

two 1200W PSU
for 2+1 redundancy, install three 1200W PSU

one 1800W PSU
for 1+1 redundancy, install two 1800W PSU

MLX-4 and
Brocade NetIron
XMR 4000

two (1x100GE)

one 1200W PSU
for 1+1 redundancy, install two 1200W PSU

MLXe-8

two

two 1200W PSU
for 1+1 redundancy, install four 1200W PSU

one 1800W PSU
for 1+1 redundancy, install two 1800W PSU

three or four

three 1200W PSU
for 3+1 redundancy, install four 1200W PSU

two 1800W PSU
for 2+2 redundancy, install four 1800Q PSU

Brocade NetIron
XMR 8000

four (1x100GE)

two 1200W PSU
for 2+2 redundancy, install four 1200W

Advertising