31

53-1002373-02

Router modules

1

Power supply requirements for Gen-1 2-port or 4-port 10 Gbps Ethernet interface modules

Table 10

lists the power supply requirements for each type of router when installing Gen-1 2-port or

4-port 10 Gbps Ethernet interface modules.

TABLE 10

Power supply requirements for Gen-1 2-port or 4-port 10 Gbps Ethernet interface modules

Router type

Number of Gen-1
2-port or 4-port Gbps
Ethernet interface
modules installed

Power supply requirements

MLXe-4

three

one 1200W PSU
for 1+1 redundancy, install two 1200W PSU

four

two 1200W PSU
for 2+2 redundancy, install four 1200W PSU

MLX-4 and
Brocade NetIron
XMR 4000

four

one 1200W PSU
for 1+1 redundancy, install two 1200W PSU

MLXe-8

seven

two 1200W PSU
for 2+2 redundancy, install four 1200W PSU

eight

three 1200W PSU
for 3+1 redundancy, install four 1200W PSU

Brocade NetIron
XMR 8000

eight

two 1200W PSU
for 2+2 redundancy, install eight 1200W PSU

All 16-slot routers sixteen

four 1200W PSU
for 4+4 redundancy, install eight 1200W PSU

All 32-slot routers thirty-two

four 2400W PSU
for 4+4 redundancy, install eight 2400W PSU

Advertising