Port 1 gbps ethernet copper rj45 interface module – Brocade Communications Systems Brocade MLX Series and Brocade Netlron XMR 53-1002373-02 User Manual

Page 54

Advertising
background image

36

Brocade MLX Series and Brocade NetIron XMR Hardware Installation Guide

53-1002373-02

Router modules

1

SYSLOG: May 28 16:22:35:<13>May 28 16:22:35 System: Module was inserted to slot 7

Module 7 is -d class, it can't work when router mpls is enabled.

Reset slot 7

SYSLOG: May 28 16:22:48 :<13>May 28 16:22:48 Module 7 is reset by mgmt (reason:

boot to interactive mode)

Power supply requirements for NI-MLX-10Gx8-M and NI-MLX-10Gx8-D modules

Table 14

lists the power supply requirements for each type of router when installing Gen-2 8-port

10 Gbps interface modules (NI-MLX-10Gx8-M and NI-MLX-10Gx8-D).

24-port 1 Gbps Ethernet copper RJ45 interface module

The 24-port 1 Gbps Ethernet copper interface module is available in the following formats:

BR-MLX-1GCx24-X-ML

BR-MLX-1GCx24-X

This module has 32 Mb of flash memory and contains 24 RJ45 physical ports, through which you
can connect your router to other network routers. BR-MLX-1GCx24-X-ML support s up to 512K IPv4
routes in hardware and BR-MLX-1GCx24-X version supports up to 1M IPv4 routes in hardware.
BR-MLX-1GCx24-X-ML does not include a software license, but can be upgraded to an X version
through a software license. Please contact Brocade to purchase the license upgrade.

TABLE 14

Power supply requirements for Gen-2 8-port 10 Gbps interface modules

Router type

Number of Gen-2
8-port 10 Gbps
interface modules
installed

Power supply requirements

MLXe-4

three

one 1200W PSU
for 1+1 redundancy, install two 1200W PSU

four

two 1200W PSU
for 2+2 redundancy, install four 1200W PSU

MLX-4 and
Brocade NetIron
XMR 4000

four

one 1200W PSU
for 1+1 redundancy, install two 1200W PSU

MLXe-8

seven

two 1200W PSU
for 2+2 redundancy, install four 1200W PSU

eight

three 1200W PSU
for 3+1 redundancy, install four 1200W PSU

Brocade NetIron
XMR 8000

eight

two 1200W PSU
for 2+2 redundancy, install eight 1200W PSU

All 16-slot routers sixteen

four 1200W PSU
for 4+4 redundancy, install eight 1200W PSU

All 32-slot routers thirty-two

four 2400W PSU
for 4+4 redundancy, install eight 2400W PSU

Advertising