Brocade Communications Systems Brocade MLX Series and Brocade Netlron XMR 53-1002373-02 User Manual

Page 353

Advertising
background image

Brocade MLX Series and Brocade NetIron XMR Hardware Installation Guide

335

53-1002373-02

Managing the cooling system

7

Fan Speed Hi: 70 - 113

state = 1 (FAN_STATE_MED)

max_ts_shut_off_count = 1

shut_off_count = 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

=== Thermal Sensor Control Block (THERMAL_SENSOR_TEST_RULE_STANDBY_MP) ===

Fan Speed Low: -1 - 60

Fan Speed Med: 57 - 70

Fan Speed Med-Hi: 67 - 80

Fan Speed Hi: 77 - 85

state = 0 (FAN_STATE_LOW)

max_ts_shut_off_count = 1

shut_off_count = 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

=== Thermal Sensor Control Block (THERMAL_SENSOR_TEST_RULE_MP_CPU) ===

Fan Speed Low: -1 - 60

Fan Speed Med: 57 - 70

Fan Speed Med-Hi: 67 - 80

Fan Speed Hi: 77 - 95

state = 1 (FAN_STATE_MED)

max_ts_shut_off_count = 1

shut_off_count = 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

=== Thermal Sensor Control Block (THERMAL_SENSOR_TEST_RULE_STANDBY_MP_CPU) ===

Fan Speed Low: -1 - 60

Fan Speed Med: 57 - 70

Fan Speed Med-Hi: 67 - 80

Fan Speed Hi: 77 - 95

state = 0 (FAN_STATE_LOW)

max_ts_shut_off_count = 1

shut_off_count = 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

Syntax: show fan-threshold

The output displays the following information.

TABLE 50

Temperature threshold information for modules and fan speeds

This field...

Displays...

Thermal Sensor Control Block
(THERMAL_SENSOR_TEST_RULE_<
module>)

The temperature threshold information for the various modules. The
<module> parameter indicates the following:

MP – The active management module

STANDBY_MP – The standby management module

SNM – The switch fabric module

LP – An interface module

Fan Speed Low or Med or Med-Hi or
Hi

The current setting of the low and high temperature thresholds for the low,
medium, medium-high, and high fan speeds.
NOTE: As indicated in

Table 49

on page 333, the low fan speed for each

module does not have a default low temperature threshold value,
nor can you configure this value. The “-1” value that appears in the
Fan Speed Low field for each module is a Brocade internal value
only.

State = 0 (FAN_STATE_LOW)

For Brocade internal use only.

max_ts_shut_off_count

For Brocade internal use only.

shut_off_count = 0 0 0 0 0 0 0 0

For Brocade internal use only.