Brocade Communications Systems Brocade MLX Series and Brocade Netlron XMR 53-1002373-02 User Manual

Page 343

Advertising
background image

Brocade MLX Series and Brocade NetIron XMR Hardware Installation Guide

325

53-1002373-02

Managing the device

7

To display this information, enter the show chassis command at any level of the CLI.

Brocade# show chassis

*** Brocade MLX-4 chassis ***

---POWERS ---

Power 1 (32011000 - AC 1200W): Installed (OK)

Power 2: not present

Power 3: not present

Total power budget for device = 1200 W

Total power used by system core = 183 W

Total power used by LPs = 386 W

Total power available = 631 W

Slot Power-On Priority and Power Usage:

Slot1 pri=1 module type=NI-MLX-1Gx20-GC 20-port 10/100/1000 Copper Module power

usage=156W

Slot4 pri=1 module type=NI-X-OC48x8 8-port OC48/12 STM16/STM4 Module power

usage=230W

--- FANS ---

right fan tray (fan 1): Status = OK, Speed = MED-HI (90%)

right fan tray (fan 2): Status = OK, Speed = MED-HI (90%)

--- TEMPERATURE READINGS ---

Active Mgmt Module: 36.500C 49.625C

Standby Mgmt Module: 36.250C 51.0C

SNM1: 37.0C

SNM2: 38.0C

SNM3: not present

LP1 Sensor1: 41.5C

LP1 Sensor2: 50.625C

LP4 Sensor1: 39.0C

LP4 Sensor2: 49.250C

LP4 Sensor3: UNUSED

LP4 Sensor4: 38.5C

LP4 Sensor5: 47.750C

LP4 Sensor6: UNUSED

Fans are in auto mode. Temperature Monitoring Poll Period is 60 seconds

Table 46

describes the show chassis command output.

TABLE 46

show chassis command output

Field

Description

Powers

Power <num>, <part num>

The Power <num> is the power supply number as positioned in the device. The
number of power supplies are as follows:
4-slot devices: 1 – 3
8-slot devices: 1 – 4
16-slot devices: 1 – 8
32-slot devices: 1 – 8
The <part num> is the part number of the power supply purchased. This
applies to AC and DC power supplies.

Advertising