Brocade Communications Systems Brocade MLX Series and Brocade Netlron XMR 53-1002373-02 User Manual

Page 46

Advertising
background image

28

Brocade MLX Series and Brocade NetIron XMR Hardware Installation Guide

53-1002373-02

Router modules

1

8x10GE-X interface module LEDs

The 8x10GE-X interface module LEDs indicate module and port status, as described in

Table 7

.

Power supply requirements for 8x10GE-X modules

Table 8

lists the power supply requirements for each type of router when installing 8x10GE-X

modules.

TABLE 7

8x10GE-X module LEDs

LED

Location

State

Meaning

Power

Lower left corner of module

Green

Module is receiving power

Off

Module is not receiving power

Link/Act

Below the ports. Top port
LED on left, bottom port LED
on right.

Green
blinking

Port enabled and link is passing traffic. LED is solid
green when link is idle.

Off

Port is disabled.

TABLE 8

Power supply requirements for 8x10GE-X modules

Router type

Number of 8x10GE-X
modules installed

Power supply requirements

MLXe-4

one

one 1200W PSU
for 1+1 redundancy, install two 1200W PSU

two to four

two 1200W PSU
for 2+2 redundancy, install four 1200W PSU

one 1800W PSU
for 1+1 redundancy, install two 1800W PSU

MLX-4 and
Brocade NetIron
XMR 4000

four

one 1200W PSU
for 1+1 redundancy, install two 1200W PSU

MLXe-8 and
Brocade NetIron
XMR 8000

seven

two 1200W PSU
for 2+2 redundancy, install four 1200W PSU

eight

three 1200W PSU
for 3+1 redundancy, install four 1200W PSU

two 1800W PSU
for 2+3 redundancy, install four 1800W PSU

All 16-slot routers fifteen

four 1200W PSU
for 4+4 redundancy, install eight 1200W PSU

sixteen

five 1200W PSU
for 5+3 redundancy, install eight 1200W PSU

four 1800W PSU
for 4+4 redundancy, install eight 1800W PSU

All 32-slot routers twenty-eight

four 2400W PSU
for 4+4 redundancy, install eight 2400W PSU

twenty-nine to
thirty-two

five 2400W PSU
for 4+4 redundancy, install eight 2400W PSU

four 3000W PSU
for 4+4 redundancy, install 3000W PSU

Advertising